Elektronika - ECFL 30
FOUR INSTRUMENTS IN ONE
- Active bridge for accurate location of faults where the level of disturbing voltages are low
- Wheatstone bridge for location of faults where the level of disturbing voltages are high
- Graaf fault locator for accurate fault location on totally watersoaked cable
- TDR to find low impedance faults and splits causing cross talk between the pairs
ACTIVE BRIDGE
- DC Fault Location Methods: Murray, 3 Point, Küpfmüller, Repeated Küpfmüller
- AC Fault Location Methods: Interruption, Repeated Küpfmüller
- Resistance difference measurement
- Loop resistance & Isolation resistance measurement
PASSIVE BRIDGE
- DC Fault Location Methods: Murray, 3 Point, Küpfmüller, Resistance difference
- AC Fault Location Methods: Küpfmüller, Capacitive Balance
- Loop resistance & Isolation resistance measurement
GRAAF FAULT LOCATOR
- End to end synchronic current measurement
TDR
- Fault location up to 32 km
REMOTE CONTROL
- ELC 30 loop closing device to open or close the far end of the tested cable
- ECFL 30S slave unit to perform synchronic end to end Graaf measurement
DISPLAY
- 320 x 240 dot graphic LCD display with backlight
- Selectable English or German languages
USB ports and PC programs
- USB B device-port for direct PC connection
- USB A host-port for USB stick(Indirect transfer)
- Optional PC program for result transfer and parameter set edition
Opmerkingen
Klik hier voeg opmerking toe
Opmerkingen en beoordelingen
Op dit moment zijn er geen opmerkingen of beoordelingen gegeven door andere bezoekers.
Documentation
| Taal | |
|---|---|
![]() |
Huur dit product
Koop dit product
Dit product is niet te koop via onze website. Neem contact met ons op voor eventuele verkoopprijzen.
Laatst bekeken producten
| Merk | Model | Beschrijving | ||
|---|---|---|---|---|
![]() |
Elektronika | ECFL 30 | Cable Fault Locator | Details » |
![]() |
Dranetz BMI | PX5 | Power Explorer | Details » |
![]() |
Doble | M5300 | Sweep Frequency Response Analyzer | Details » |
![]() |
Doble | PDS100 | Handheld partial discharge (PD) detector | Details » |
![]() |
Doble | F6150 | Power System Simulator | Details » |